The Fact About Olympus Magna-Mike 8600 Thickness Gauge Brochure That No One Is Suggesting

Calibration: Hall Result devices must be calibrated before use, using the very same probe and target that should be employed for measurements. This is often completed by having readings without having target, Together with the focus on touching the probe (zero thickness), and at two or even more reference thicknesses. This permits the instrument to deliver a calibration desk that plots voltage variations as opposed to thickness.

Probe orientation: As the Magna-Mike 8600 measures thickness by monitoring small adjustments in a very magnetic discipline, its calibration method involves an automatic payment for the results of the earth's magnetic industry. Mostly, the probe is held at a relentless orientation, vertically inside of a stand. On the other hand in situations where by the probe is used at a unique orientation (for example getting held horizontally), or if the orientation is switching as in scanning the surface of the curved section, calibration must be up to date.

The common probe with one of several two goal disks and also a replaceable chisel have on cap makes the Magna-Mike 8600 gauge Preferably suited to most automotive tear seam applications exactly where measurements have to be designed in a thin channel or groove.

The Magna-Mike has an intensive file-primarily based alphanumeric details logger that is certainly intended to effortlessly retail outlet and transfer thickness readings.

If an unidentified goal error message occurs throughout calibration, it ensures that the gage is unable to recognize the focus on or goal ball.

A white dot indicates that the user has chosen a standard dress Olympus Magna-Mike 8600 Thickness Gauge Brochure in tip. A white triangle indicates which the chisel don tip has become selected. Site fifty seven: Menus And Submenus

The PDW thirty collection products attribute two totally free piston assemblies, allowing for for the appliance of the two small strain array with smaller ways and high force array with more substantial techniques. This integration into an individual instrument results in significant Value price savings.

Regardless if you are seeking greater solutions for 3D imaging and Evaluation, entire slide scanning, cell tradition solutions, or custom made alternatives, we can offer equipment to speed up your discovery workflow.

The production means of these drinks is rather vital as these beverages ought to have a particular number of carbonation to attain shopper fulfillment amounts and greatly enhance The client working experience.

The probe's Hall Influence sensor steps the distance between the probe suggestion and focus on ball. The measurements are instantaneously displayed on the big color thickness Display screen as a fairly easy-to-browse digital thickness looking through.

This guide is made up of vital info on how to use this Olympus products safely and successfully.

The Magna-Mike can be a Hall Impact thickness gage that uses a magnetic probe to perform correct measurements on nonferrous and slim elements like plastic bottles.

If the probe is replaced, dropped, or contacts really-magnetic materials Be aware In case the Magna-Mike 8600 has just been turned on, or if a probe has just been linked, allow the gage to heat up for a minimum of five minutes Along with the probe connected in advance of undertaking a calibration. Site 86: Table nine Calibration Accuracy For your 86Pr-3 Probe

Wire targets: When using the wire goal, the probe suggestion should be positioned at the least one in. (25 mm) within the conclude of the wire. The wire must be pressed securely from the check piece at The purpose of measurement, considering that as with any other focus on the Magna-Mike is actually measuring the space on the concentrate on, not the wall thickness directly.